Classification: | Defibrillator Monitor |
---|---|
Type: | Defibrillator Monitor |
Certification: | CE, ISO13485 |
Group: | All People |
Display: | 8 Inch High Resolution LCD Display |
Defibrillator Waveform: | Biphasic |
Customization: |
---|
Suppliers with verified business licenses
Defibrillator Monitor
Specification
- Display
Display Type: 8 inch high resolution LCD display
Sweep Speed: 25mm/sec
Information: HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts. Alarm Se.lection and Limits, Delivered Energy.
Specification | MB_pacer (Optional) |
Type | VVI |
Pulse Type | rectangular,constant current |
Pulse Amplitude | 0 to 180 mA+10% or 5 mA(whichever is greater) |
Pacing Rate | Variable from 30 ppm to 180 ppm 1.5% (increments ordecrements by a value of 2 ppm) |
Multi-Function Electrode(MFE)Pads | multipurpose defibrillation/pacing electrodes |
Pause | Pacing pulse frequency reduced by a factor of 4 whenactivated |
Refractory Period | NC(VVI demand do not have this specification) |
Pulse Width | (20+ 1.5 ms) |
Output Protection | Fully defibrillator protected and isolated |
Specification | MB EtCO2 (Optional) |
Type of sensor | By-pass |
Technical principle | Non-dispersiveinf rared gas analysis NDIR |
Storage condition | -40°C to 70C,<90% RH, non-condensing |
Operating conditions | 5°C to 50°C,10 to 90% RH, non-condensing |
Ambient pressure | 55-115kPa |
Power supply | 5 V+5%(max ripple 200 mVp-p) |
TDP | Typical value120mA Excursion calibration typicalvalue280mA |
Range | 0-19.7%(0-150mmHg,or 0-20kPa) |
Resolution | 0.1mmHg |
Accuracy | 0 - 40 mmHg + 2 mmHg 41 - 70 mmHg ± 5% ofreading 71 - 100 mmHg +8% of reading 101 - 150 mmHg10% of reading |
Respiratory rate | 2-150 BPM |
Respiratory rate measurement accuracy |
1%±1BPM |
Specification | MB_NIBP (Optional) |
Measurement unti: | mmHg/kPa |
Measurement Range : | Adult:10~270 mmHg/kPa |
Pediatric:10~200 mmHg/kPa Neonatal: 10~135 mmHg/kPa |
|
Resolution | 1 mmHg |
Accuracy: | Maximum mean error:5 mmHg Maximum standard deviation:8 mmHg |
Type of sensor | By-pass |
Technical principle | Non-dispersive infrared gas analysis NDIR |
Storage condition | -40C to 70C, <90% RH, non-condensing |
Operating conditions | 5°C to 50C,10 to 90% RH, non-condensing |
Ambient pressure | 55-115kPa |
Power supply | 5 V +5%(max ripple 200 mVp-p) |
TDP | Typical value 120mA Excursion calibration typical value 280mA |
Range | 0-19.7%(0-150mmHg,or 0-20kPa) |
Resolution | 0.1mmHg |
Accuracy | 0 - 40 mmHg ±2 mmHg 41 - 70 mmHg + 5% of reading 71 - 100 mmHg 8% of reading101 - 150 mmHg ±10% of reading |
Respiratory rate | 2-150 BPM |
Respiratory rate measurement accuracy |
1%+1BPM |
Specification | SPO2 Moudle (Optional) |
Measurement Range: | 30~100%+2% between 80%~90%,Others +5% |
Alarm Range | User set high limit and low limit |
Alarm Accuracy | +10 within setting values |
Alarm Time Accuracy | Less than 12 sec |