Defibrillator Monitor with LCD Display

Classification: Defibrillator Monitor
Type: Defibrillator Monitor
Certification: CE, ISO13485
Group: All People
Display: 8 Inch High Resolution LCD Display
Defibrillator Waveform: Biphasic
Customization:
Manufacturer/Factory, Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Shandong, China
  • Overview
  • Product photo
  • Product details
Overview

Basic Info.

Model NO.
GP-DM7000
ECG Size
0.25, 0.5,1, 1.5, 2, 4 Cm/Mv Diplay on Monitor
Recorder Paper
50mm Thermal
Transport Package
Standard Export Carton
Specification
25mm/sec
Trademark
Hiprove
Origin
Shandong, China

Product Description

Product photo

 

Defibrillator Monitor with LCD Display
Defibrillator Monitor with LCD Display
Defibrillator Monitor with LCD Display
Defibrillator Monitor with LCD Display
Defibrillator Monitor with LCD Display

 
Product details

Defibrillator Monitor

Specification

- Display
Display Type: 8 inch high resolution LCD display
Sweep Speed: 25mm/sec
Information: HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts. Alarm Se.lection and Limits, Delivered Energy.

- Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.


- ECG Monitoring
Patient Connection:5-lead ECG cable, or 3-lead ECG cable, paddles.
Lead Selection: Displayed on monitor, paddles, l, l, Ill, AVR, AVL, AVF,V.
ECG Size: 0.25, 0.5,1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
Smart Alarms: Beeper/voice prompts indicate shockable rhythm.

- Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec,25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution, thermal print head.
Print-out Modes: Manual or automatic,user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator chargeor defibrillator discharge.

- Battary
Type: Rechargeable, Ni-MH battery,12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximumenergy, or 3 hours minimum of continuous ECG monitoring.Additional parameters will effect operating time with different functions.
AED Mode
AED Function: Auto analyze and charge X3 with programmable auto energy level selection,screen prompts,and voice prompts.
Shockable Rhythms: Ventricular fibrilation with amplitude >=200UV, ventricular tachycardiawith rates >=140bpm,and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel, press key on paddle.
Prompts: Voice and visual prompts.

- Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave."SYNC" messagedisplayed on monito.

 
Specification MB_pacer (Optional)
Type VVI
Pulse Type rectangular,constant current
Pulse Amplitude 0 to 180 mA+10% or 5 mA(whichever is greater)
Pacing Rate Variable from 30 ppm to 180 ppm 1.5% (increments ordecrements by a value of 2 ppm)
Multi-Function Electrode(MFE)Pads multipurpose defibrillation/pacing electrodes
Pause Pacing pulse frequency reduced by a factor of 4 whenactivated
Refractory Period NC(VVI demand do not have this specification)
Pulse Width (20+ 1.5 ms)
Output Protection Fully defibrillator protected and isolated
 
Specification MB EtCO2 (Optional)
Type of sensor By-pass
Technical principle Non-dispersiveinf rared gas analysis NDIR
Storage condition -40°C to 70C,<90% RH, non-condensing
Operating conditions 5°C to 50°C,10 to 90% RH, non-condensing
Ambient pressure 55-115kPa
Power supply 5 V+5%(max ripple 200 mVp-p)
TDP Typical value120mA Excursion calibration typicalvalue280mA
Range 0-19.7%(0-150mmHg,or 0-20kPa)
Resolution 0.1mmHg
Accuracy 0 - 40 mmHg + 2 mmHg
41 - 70 mmHg ± 5% ofreading
71 - 100 mmHg +8% of reading
101 - 150 mmHg10% of reading
Respiratory rate 2-150 BPM
Respiratory rate measurement
accuracy
1%±1BPM
 
Specification MB_NIBP (Optional)
Measurement unti: mmHg/kPa
Measurement Range : Adult:10~270 mmHg/kPa
  Pediatric:10~200 mmHg/kPa
Neonatal: 10~135 mmHg/kPa
Resolution 1 mmHg
Accuracy: Maximum mean error:5 mmHg
Maximum standard deviation:8 mmHg
Type of sensor By-pass
Technical principle Non-dispersive infrared gas analysis NDIR
Storage condition -40C to 70C, <90% RH, non-condensing
Operating conditions 5°C to 50C,10 to 90% RH, non-condensing
Ambient pressure 55-115kPa
Power supply 5 V +5%(max ripple 200 mVp-p)
TDP Typical value 120mA Excursion calibration typical value 280mA
Range 0-19.7%(0-150mmHg,or 0-20kPa)
Resolution 0.1mmHg
Accuracy 0 - 40 mmHg ±2 mmHg
41 - 70 mmHg + 5% of reading 71 - 100 mmHg  8% of reading101 - 150 mmHg ±10% of reading
Respiratory rate 2-150 BPM
Respiratory rate
measurement accuracy
1%+1BPM
 
Specification SPO2 Moudle (Optional)
Measurement Range: 30~100%+2% between 80%~90%,Others +5%
Alarm Range User set high limit and low limit
Alarm Accuracy +10 within setting values
Alarm Time Accuracy Less than 12 sec

Product Feature

Defibrillator Monitor with LCD Display

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Management System Certification
GMP, BSCI, ISO 13485, FSC
OEM/ODM Availability
Yes