Mbj20 Transdermal Neonatal Jaundice Detector for Medical Infants

Product Details
Customization: Available
Theory: Autoclave
Type: Pressure Steam Sterilization Equipments
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Mbj20 Transdermal Neonatal Jaundice Detector for Medical Infants
  • Mbj20 Transdermal Neonatal Jaundice Detector for Medical Infants
  • Mbj20 Transdermal Neonatal Jaundice Detector for Medical Infants
  • Mbj20 Transdermal Neonatal Jaundice Detector for Medical Infants
  • Mbj20 Transdermal Neonatal Jaundice Detector for Medical Infants
  • Mbj20 Transdermal Neonatal Jaundice Detector for Medical Infants
Find Similar Products

Basic Info.

Model NO.
MBJ20
Certification
ISO13485
Electric Tension
220V
LCD Display
With LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
PP
Transport Package
1PCS/Bag
Specification
1pcs/bag
Trademark
hiprove
Origin
China
HS Code
3926909090
Production Capacity
600000

Product Description

Mbj20 Transdermal Neonatal Jaundice Detector for Medical InfantsMbj20 Transdermal Neonatal Jaundice Detector for Medical InfantsMbj20 Transdermal Neonatal Jaundice Detector for Medical InfantsMbj20 Transdermal Neonatal Jaundice Detector for Medical InfantsMbj20 Transdermal Neonatal Jaundice Detector for Medical InfantsMbj20 Transdermal Neonatal Jaundice Detector for Medical InfantsMbj20 Transdermal Neonatal Jaundice Detector for Medical Infants
product name MBJ20 Transdermal Neonatal Jaundice Detector
Standard configuration
Percutaneous jaundice detector, aluminum alloy box, instruction manual

1. Installing batteries for use
Take out the host, remove the back cover, and install two new No. 5 batteries
2. Remove the probe protective cap
When using the machine for probe flash detection, the protective cap needs to be removed
3. Press the RESET button after turning on the device
Slide the switch at the back of the instrument to the ON position, start the detector, and after starting, the LCD screen will display 0.00MG/DL. After 1 second, the READY light will turn on
4. READY lights up to start testing
Place the probe vertically close to the tested area: Press the machine, the probe flashes, and the value on the screen is the jaundice value. If you need to test again, please press the RESET button directly and repeat steps 4-5