• 80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge
  • 80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge
  • 80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge
  • 80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge
  • 80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge
  • 80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge

80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge

After-sales Service: Online
Warranty: Online
Disposable: Non-Disposable
Certification: CE, ISO
Power Source: Electric
Material: Rubber / Plastic
Customization:
Manufacturer/Factory, Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Shandong, China

Basic Info.

Model NO.
80-2
Weight
6kg
Speed
100r/Min
Transport Package
Box
Specification
1set/box
Trademark
hiprove
Origin
China
HS Code
8421192000
Production Capacity
5000/Year

Product Description

80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge

 

First, table model electrically operated centrifuge 800Product synopsis:

Table model electrically operated centrifuge 800Is the conventional laboratory to use the centrifuge, widely applies in scientific research educationsthe production departmentso on the biology, chemistry, medicine.Low speed table model centrifuge highest rotational speed 4000R/MIN, is suitable for the emission immunity appraisalthe separation cellthe big particle, has may fixed timemay not fixed time two kinds.

 

Second, table model electrically operated centrifuge 800Technical specification:

Model

Highest rotational speed

Capacity

Most greatly relative centrifugal force

Power source

800

4000rpm

20ml×6

1435xg

AC220V 50HZ

 

Model

Highest rotational speed

Capacity

Relative centrifugal force

Fixed time scope

Power source

80-1

4000rpm

20ml×6

1795xg

0-60min or Chang Kai

AC220V 50HZ

80-2

4000rpm

20ml×12

1795xg

0-60min or Chang Kai

AC220V 50HZ

 
80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge80-2 Laboratory Small Beauty Electric Desktop Low Speed Centrifuge80-2 Bmodel  Operating instruction for electric centrifuge


A  Summary:
Centrifugal separation technology is a new technology developed according to the state of particles in a practical centrifuge. Particles of different densities, sizes, and shapes settle in centrifugation at different speeds, so a roughly spherical, heterogeneous mixture can be separated by centrifugation. The centrifuge is to separate a large number of substances without studying biochemistry. For example, collect cells, separate plasma, separate DNA and proteins from these purified formulations, and isolate viruses and large - scale e. coli.
B  Main technical parameters:
1: use the power supply. Ac 220 v50hz                  
2: motor power. 60 w                                   
3: turn speed. 500-4000 revolutions per minute          
4: centrifugal capacity. 20 ml x 12.  20 ml x 8
5: timing range. 1-60 min or normally open
6: RCF. 2350 xg
C: use safety instructions
Remember to follow the following safety precautions when using this product:
1.Read all instructions.
2.The electrical rated parameters of the socket provided by the user shall not be less than the electrical rated parameters of the machine and have good grounding measures.
3.When replacing the fuse, pull the power plug out of the socket.
4.After the instrument breaks down, it should be repaired by professionals. The use of accessories not recommended by the manufacturer will cause certain quality problems.
  1. When the rotor of the centrifuge is running, it is strictly forbidden to open the cover, and the rotor must be stopped completely. To open the cover to remove the centrifugal tube.
  2. The instrument is strictly prohibited to move during operation.
  3. All kinds of liquid or other sundries are strictly forbidden to enter the working room of the centrifuge, otherwise the main engine will be damaged.
  4. Instruments in use, should be looked after.
9.  The power should be cut off before cleaning the machine.



10. The instrument should be used in a dry environment to avoid accidents caused by damp.

80-2 Bmodel  Operating instruction for electric centrifuge

 instructions
  1. The instrument should be placed on a stable work table, the environment should be clean and tidy, temperature, humidity and good ventilation.
  2. Set the speed adjustment knob to the minimum position before using the instrument.
The centrifugal tubes which need to be separated are inserted into the centrifugal tubes respectively. In order to make the instrument work smoothly. Avoid large vibrations. The material added to each centrifuge tube must be basically equal. And inserted symmetrically into the centrifugal tube. and then closed the cover plate.
4.  Choose timing, the timing knob transferred to the "timing" or "ON" position.
5.  Turn on the power supply and slowly adjust the speed control knob to the required speed.
6.  Before the shutdown, the speed control knob must be placed in the minimum position to turn off the power switch and cut off the power supply
E:maintaining
  1. Use the instrument correctly and pay attention to the maintenance of the instrument, make it in good working condition, can extend the service life of the instrument.
  1. The instrument should be checked regularly three months during continuous operation:Check whether there is water drop, dirt, etc. falling into the motor and control assembly, check carbon brush, fuse, control assembly and fastening screw,After using for a period of time, if the speed of the centrifuge becomes slow, please check the carbon brush and replace it in time.(Replacement method: cut off the power, open the bottom plate, remove the circular plastic cap near the bottom of the motor, and replace the old carbon brush with the new one)
  2. After long-term use of the instrument, natural wear is normal. If the machine is found to have abnormal noise, bearing wear of the motor, failure of electronic control components and other faults after one year of use, the company will continue to provide quality services and provide assistance .

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Management System Certification
GMP, BSCI, ISO 13485, FSC
OEM/ODM Availability
Yes